OUR PRODUCTS
Wet-Repel™
Aquacrete Wet-Repel™ is a water-resistant, single component, high-strength product that provides ventilation control and geology consolidation in underground mines. Developed specifically for applications where conditions may result in erosion from water, Aquacrete Wet-Repel™ achieves a new benchmark in ventilation control performance.




Product Features
Safer
- Low toxicity
- Fire resistant
- Anti-static
- Creates an explosion-rated ventilation control device
- Cures to off-white colour
Faster
- Aquacrete Wet-Repel™ can be applied to any desired thickness in a single application
- Aquacrete Wet-Repel™ is rapid-setting and achieves the specified rating within 24 hours and a compressive strength of 17 MPa in as little as 48 hours and up to 25 MPa in 28 days
- Aquacrete Wet-Repel™ does not slump
Stronger
- Aquacrete Wet-Repel™ complies with mining industry over-pressure and thickness requirements for ventilation control devices (Queensland Department of Mines & Energy)
- Product certification has been issued by an accredited National Association of Testing Authorities (NATA) laboratory for over-pressure performance in a live underground blast test
Product Applications
In addition to addressing more severe gas and water ingress concerns, Aquacrete Wet-Repel™ is increasingly specified by underground mines throughout Australia for a wide range of applications.
These include:
- Rated ventilation stoppings
- Rated ventilation seals
- Non-rated segregation stoppings
- Dam walls
- Bulkheads
- Overcasts and overcast wings
- Rib consolidation and longwall rib consolidation
- Stopping and seal repairs
Product Testing & Certification
To ensure that Aquacrete Wet-Repel™ conforms to the most stringent industry standards, testing and certification is undertaken by laboratories approved by the National Association of Testing Authority (NATA). These include Western Geotechnics Group.
| Test Date | Age at Test | Test Description | Industry Standard/Specification | Certificate Number | Results |
|---|---|---|---|---|---|
| 29/09/2005 | 2 days | Compressive strength and mass per unit volume of hardened concrete | AS 1012 Part 14, 12.1 | WG 111340 | 13 MPa |
| 19/05/2008 | 2 days | Compressive strength of concrete | AS 1012.9 | KG 30633 | 10 MPa |
| 17/10/2008 | 2 days | Compressive strength and mass per unit volume of hardened concrete | AS 1012.14, AS 1012.12.2 | 73342 | 17 MPa |
| 6/11/2008 | 2 days | Compressive strength and mass per unit volume of hardened concrete | AS 1012.9 & AS 1012.12.1 | 08-KG-389-C300 | 14 MPa |
| 24/05/2008 | 7 days | Compressive strength of concrete | AS 1012.9 | KG 30716 | 14 MPa |
| 22/10/2008 | 7 days | Compressive strength and mass per unit volume of hardened concrete | AS 1012.14, AS 1012.12.2 | 73343 | 17 MPa |
| 11/11/2008 | 7 days | Compressive strength and mass per unit volume of hardened concrete | AS 1012.9 & AS 1012.12.1 | 08-KG-389-C300 | 15 MPa |
| 27/10/2005 | 28 days | Compressive strength and mass per unit volume of hardened concrete | AS 1012 Part 14, 12.1 | WG 111340/1 | 17.5 MPa |
| 24/05/2008 | 28 days | Compressive strength of concrete | AS 1012.9 | KG 30716 | 19 MPa |
| 12/11/2008 | 28 days | Compressive strength and mass per unit volume of hardened concrete | AS 1012.14, AS 1012.12.2 | 73344 | 14 MPa |
| 2/12/2008 | 28 days | Compressive strength and mass per unit volume of hardened concrete | AS 1012.9 & AS 1012.12.1 | 08-KG-389-C300 | 25.5 MPa |
| 1/10/2005 | 2 days | Determination of modulus of rupture of concrete specimens | AS 1012.11 | WG 110153 | 3.2MPa |
| 1/10/2005 | 28 days | Determination of modulus of rupture of concrete specimens | AS 1012.11 | WG 110153 | 2.7MPa |
| 10/10/2005 | n/a | Direct shear, single stage on intact specimen | ISRM Pt. 2 | WG 110153 | 1,594kPa |
| 27/10/2005 | n/a | Determination of water absorption and apparent volume of permeable voids in hardened concrete | AS 1012.21 | WG 111341 | 17.90% |